PV-LOK PWP-C24 bell joint restraint with its restraining rods, nuts and washers

Photos show several models and sizes. Your restraint is in the item number.

Item # PWP-C8 Questions and answers (7)

PV-LOK Serrated Restraints

Serrated restraints for PVC pipe, 2 to 48 in., at bell joints, ductile iron fittings and PVC fittings. Pick the pipe, the joint and the model, then the size and coating.

 

  • Machined serrations, not as cast, grip the PVC pipe wall and support it fully
  • Rated to the working pressure of the PVC pipe it is installed on, within each catalog's limits
Pipe: C900/C905
Joint: Bell joint
Model: PWP
Size: 8 in.
Made: Import

Need it domestic? Pick Domestic.

Coating: Standard

Standard shop coating on the ductile iron rings.

Your distributor

SIGMA sells through waterworks distributors. Order with item # PWP-C8.

Quote from SIGMA

Sends your quote list to the right regional team.

Download the PV-LOK PWP submittal

Need help on the job?

Call 800.999.2550 with the pipe, the joint and the size.

Everything about the 8 in. PV-LOK PWP.

Details, specs, every size and the questions buyers ask. Open what you need.

Product detailsWhat it is, highlights and documents

About PV-LOK

PV-LOK is SIGMA's serrated restraint for PVC pipe. A split ductile iron ring with machined serrations, not as cast, clamps onto the pipe and grips the wall; rods or bolts tie it back across the joint.

Pick the pipe and the joint above, then the model. C900/C905 models fit PVC made to the ductile iron pipe OD, 4 to 48 in.; IPS models fit PVC made to the steel pipe OD, 2 to 12 in. The PT models have bi-directional serrations.

Ratings by pipe class, dimensions, drawings and installation steps are in each model's catalog, under Documents.

Highlights

  • C900/C905 PVC, 4 to 48 in.; IPS PVC, 2 to 12 in.
  • Split ductile iron clamping ring, ASTM A536 Grade 65-45-12, with machined serrations
  • Standard coating, or CorrSafe e-coat where the price list shows it
Specifications8 in. PV-LOK PWP

8 in. PV-LOK PWP

Item numberPWP-C8
ModelPWP: Bell joint restraint
Size8 in.
MadeImport
CoatingStandard
Pressure ratingEqual to the PVC pipe it is installed on, within the limits in the model's catalog (see Ratings and use)
Weight27.00 lb
Catalog pagePage 2 of the model's catalog
Price listImport Restraint Products, effective 12/9/24, rev. 4/14/26

Materials

Clamping ringDuctile iron, ASTM A536 Grade 65-45-12, with machined serrations
Side clamping bolts and nutsHigh-strength steel per ASTM A449, zinc plated
Rods, T-bolts and nutsHigh-strength low-alloy steel per ANSI/AWWA C111/A21.11
CoatingStandard coating, or CorrSafe epoxy e-coat (a cationic epoxy coating applied by electrodeposition) where the price list shows it
Hardware optionsType 304 or 316 stainless steel, or blue fluoropolymer-coated hardware, on PWM, PWP and PWH (September 2026 submittals); stainless steel or fluoropolymer-coated hardware on PTM, PTP and PTPF (their catalogs): ask your regional team

Ratings and use

Pressure ratingEqual to the working pressure of the PVC pipe it is installed on. The PWM, PWP, PWPF, PVM and PVP catalogs list ratings by pipe class; the PWH catalog lists 235 psi
Safety factorMinimum 2:1 in the sample specifications of the PWM, PWP, PWPF, PTM, PTP, PTPF, PVM, PVP and PVPF catalogs, and 2:1 in the PWH submittal. The PWM catalog derates it at push-on joints that do not take all the rods
PWM at a push-on fitting200 psi at 4 to 8 in.; 75 psi at 10 and 12 in. with 2 restraining rods, per the PWM catalog
On ductile iron pipePWP, 4 to 12 in.: 250 psi at 4 to 8 in. and 200 psi at 10 and 12 in., per the PWP catalog. PTP and PTM: ask your regional team
C909 PVCO pipePWP-C and PWM-C, 4 to 30 in., at 165 or 235 psi per SIGMA's C909 sheet (May 2026); do not over-tighten the T-bolts
Pipe in a casingPWM, PTM, PVM, PWP, PTP and PVP: add at least 1-1/2 in. to the catalog B dimension for clearance. PWH: ask your regional team

Installation

Bell joints (PWP, PTP, PVP)Make up the joint. Clamp one ring about 2 in. behind the insertion mark and one right behind the bell, then snug the rod nuts about one turn with a wrench
DI fittings (PWM, PTM, PVM)Mark the pipe from the extra-long T-bolt (or rod), make up the mechanical joint to AWWA standards, clamp the ring at the mark, then snug the retaining nuts
PVC fittings (PWPF, PTPF, PVPF)Set the beveled back-up ring behind the fitting bell, bevel toward the fitting end (follow the arrows on the ring), clamp the serrated ring about 2 in. in from the rod ends, then snug the nuts on both rings
PWH harnessClamp the ring about 2 in. behind the insertion mark, set the two-piece back-up ring behind the bell, then snug the rod nuts
Every modelTighten the side clamping bolts to the torque in the catalog, where it lists one. On single-direction models, face the ears as the catalog shows. Do not over-tighten the retaining nuts

From each model's PV-LOK catalog and the PWM, PWP and PWH submittals (September 2026); dates under Documents. Dimensions, drawings and, for most models, torque values are in the catalog.

Every size and item number14 sizes of the PV-LOK PWP · Import, Standard · item numbers

Showing the PV-LOK PWP, Import, Standard. Item numbers follow the options above. Pick a size to load it.

PV-LOK: item numbers and weights by size
SizeItem #Weight
PWP-C4 14.36 lb
PWP-C6 16.44 lb
PWP-C8 27.00 lb
PWP-C10 44.40 lb
PWP-C12 50.64 lb
PWP-C14 101.61 lb
PWP-C16 115.15 lb
PWP-C18 164.97 lb
PWP-C20 234.50 lb
PWP-C24 288.50 lb
PWP-C30 463.75 lb
PWP-C36 520.40 lb
PWP-C42 983.76 lb
PWP-C48 1058.50 lb

Weights from the PWM, PWP and PWH submittals (September 2026) and the other models' catalogs; D-PWP shows the PWP values. Blank where neither shows one.

Questions and answers7 questions buyers ask about PV-LOK

Where do I find the price?

On SIGMA's price lists. Where an item is on a posted list, the View price list button near the top of this page opens it, and every posted list is on the Price Lists page. SIGMA sells through waterworks distributors, and your distributor sets your price. For contract pricing, ask your regional team.

PV-LOK or ONE-LOK SLCE: which one?

Both restrain PVC pipe. PV-LOK clamps a ring with machined serrations around the pipe and ties it back with rods or bolts: at a bell joint, a ductile iron fitting or a PVC fitting. ONE-LOK SLCE is a wedge-action gland for the mechanical joint itself. The Selection Tool narrows it by pipe, size and pressure.

C900/C905 or IPS: how do I tell?

By the pipe's outside diameter. C900/C905 PVC is made to the ductile iron pipe OD, and its PV-LOK item numbers carry -C before the size, as in PWM-C8. IPS PVC is made to the steel pipe OD, and its item numbers carry -S, as in PVM-S8. An 8 in. C900 pipe is 9.05 in. OD; an 8 in. IPS pipe is 8.63 in. OD.

What pressure is a PV-LOK rated for?

The working pressure of the PVC pipe it is installed on. The PWM, PWP, PWPF, PVM and PVP catalogs list ratings by pipe class: PWP on C900 DR18 pipe is 235 psi (4 to 36 in.), for example, and on DR25 pipe 165 psi. The PWH catalog lists 235 psi. At a push-on fitting joint with ear lugs, the PWM catalog sets 200 psi at 4 to 8 in. and 75 psi at 10 and 12 in. (with 2 restraining rods).

Which models have list prices?

PWM, PWP, PVM and PVP in every catalog size, PWPF from 4 to 12 in. and PVPF from 4 to 8 in. are on the Import Restraint Products price list, in standard coating or CorrSafe e-coat. D-PWP, 4 to 12 in., is on the Domestic Pipe Restraint Products price list. PWH, PTM, PTP and PTPF, and the other PWPF and PVPF sizes, are in SIGMA catalogs and priced by request.

Can PV-LOK go on ductile iron pipe?

PWP can, from 4 to 12 in.: its catalog rates it 250 psi at 4 to 8 in. and 200 psi at 10 and 12 in. on ductile iron pipe. For PTP and PTM on ductile iron pipe, ask your regional team. For the mechanical joints on ductile iron pipe, see ONE-LOK SLDE.

Does PV-LOK work on C909 PVCO pipe?

PWP-C and PWM-C do, from 4 to 30 in., per SIGMA's sheet for AWWA C909 pipe (May 2026). The sheet also lists ONE-LOK SLCE (4 to 30 in.) and SLCS (4 to 12 in.). The restraint's rated pressure is limited to the pipe's, and the sheet rates them at 165 and 235 psi; for higher, ask your regional team. On C909 pipe, do not over-tighten the T-bolts.

How a PV-LOK goes on.

Three basic steps. Each catalog has the drawing and the details.

Make up the joint.
Clamp the serrated ring.
Tie it back.
Two crew members tightening a PV-LOK bell joint restraint on blue PVC pipe

Shown: a crew restraining a PVC bell joint.

PV-LOK split clamping ring, top view, with PV-LOK and the part number cast on the ring

Shown: a PV-LOK split clamping ring.

PV-LOK bell joint restraint tied across a PVC pipe joint with restraining rods

Shown: a bell joint restraint on PVC pipe.

Fittings and wedge-action restraints.

Ductile iron MJ fittings for the fitting end, and ONE-LOK restraints for PVC and ductile iron pipe.

SIGMA C153 mechanical joint 45 degree bend

C153 MJ fittings

Compact mechanical joint fittings, 2 to 64 in.

See C153 MJ ›

ONE-LOK SLCE restraint for PVC pipe

ONE-LOK SLCE

Wedge-action restraint for PVC pipe at a mechanical joint, 3 to 60 in.

PVC Pipe Restraints ›

ONE-LOK SLDE wedge-action gland, face view

ONE-LOK SLDE

Wedge-action restraint for the mechanical joints on ductile iron pipe.

See SLDE ›

Pricing a job?

Send your quote list to your regional team, or call.